VS1 12kV Indoor High-Voltage Vacuum Circuit Breaker

630–3150 A, 20–31.5 kA;
Features embedded poles and a spring-operated mechanism; available in withdrawable and fixed versions; IEC certified.
Self-developed mechanism structure with high-grade internal components for reliable switching in power distribution — CE certified, 10-year warranty.

Request a Quote
  • Overview

Overview

VS1 12KV Indoor HV Vacuum Circuit Breaker — Product Overview

The VS1 12KV Indoor HV Vacuum Circuit Breaker 630-3150A 20-31.5KA Embedded Pole Spring Mechanism Drawout &Fixed IEC Certified VCB from JYDQ is a 12kV withdrawable handcart-type protection device for KYN28A-12 metal-clad switchgear. Rated current range 630–3150A and rated breaking current 20–40kA, this IEC 62271-100 and KEMA-certified VCB delivers 20,000-operation mechanical endurance and 50 fault-clearing operations at 31.5kA — the performance baseline for applications where switchgear reliability and long-term maintenance cost are the primary selection criteria.

1.PRODUCT GENERAL INFORMATION

Place of Origin

Zhejiang, China

Brand Name

JYDQ

Model Number

ZN63(VS1)-12 Series

Certification

ISO 9001, KEMA, IEC 62271-100, GB 1984

Rated Voltage

12kV

Rated Current

630/1250/1600/2000/2500/3150A

Rated Breaking Current

20/25/31.5/40kA

Installation

Indoor withdrawable handcart for KYN28A-12

Interruption Medium

Vacuum interrupter

Mechanical Life

20,000 operations

Electrical Life

50 (31.5kA) / 30 (40kA)

1(53cfcb7cc9).jpg2(0b4fb49d11).jpg3(7a24ed2bb0).jpg4(a11b232ed3).jpg5(899500ee4e).jpg6(9dca2a00d4).jpg7.jpg

2. COMMERCIAL TERMS

MOQ

1 Set

Price

FOB Ningbo/Shanghai, on request

Packaging

Export-standard plywood case with vacuum-sealed moisture barrier

Delivery

20-35 working days

Payment

T/T, L/C at sight

Supply Ability

500 Sets per Month

3. PRODUCT DESCRIPTION

The ZN63(VS1)-12 Series VS1 12KV Indoor HV Vacuum Circuit Breaker 630-3150A 20-31.5KA Embedded Pole Spring Mechanism Drawout &Fixed IEC Certified VCB employs three independently sealed vacuum interrupter poles on a withdrawable handcart chassis. Each interrupter uses high-purity CuCr contact materials in a ceramic or glass envelope evacuated to 10-4 Pa — a sealed-for-life design requiring zero field maintenance over a 30-year service life. The motor-driven stored-energy spring mechanism stores closing energy within 15 seconds and supports the standard O-0.3s-CO-180s-CO auto-reclose sequence. Breaking time from trip coil energization is under 60ms, ensuring rapid fault clearance that minimizes arc energy and contact erosion. The handcart incorporates a screw-type racking mechanism with positive interlocks permitting movement only between isolated, test, and service positions — preventing operator error during insertion and withdrawal.

Capacitor bank switching is rated for 630A single bank and 400A back-to-back, confirming restrike-free vacuum interruption for power factor correction circuits. In systems protecting oil-filled transformers, restrike-free operation prevents switching overvoltages that accelerate transformer oil type insulation aging — directly mitigating transformer failure modes such as dielectric stress and incremental winding damage in high-switching-frequency applications. Auxiliary contacts (8NO+8NC), mechanical position indication, non-resettable operation counter, and both mechanical and electrical anti-pumping protection complete the control interface. Full KYN28A-12 dimensional compatibility enables seamless integration into new panel construction and retrofit switchgear projects.

A16c3ce0879a44ebb90aef66670a9e90aO.jpgA46fb3c2044f442c98b038a39b60e56f0x.jpgA587da9f9e1e44e3681bbcc288cc6a015S.jpgA4b27f010397b409b921add81e081aeed0.jpg

4. Circuit Breaker Technical Parameters (12kV)

Parameter

Unit

Value

Rated voltage

kV

12

1min power frequency withstand voltage

kV

42

Lightning impulse withstand voltage (peak)

kV

75

Rated current

A

630, 1250, 1600, 2000, 2500, 3150

Rated short-circuit breaking current

kA

20, 25, 31.5, 40

Rated short-circuit making current (peak)

kA

50, 63, 80, 100

Rated short-time withstand current

kA

20, 25, 31.5, 40

Rated short-circuit duration

s

4

Nominal operation sequence

—

O-0.3s-CO-180s-CO

Breaking time

ms

< 60

SC breaking times (31.5kA / 40kA)

times

50 / 30

Single capacitor bank breaking current

A

630

Back-to-back capacitor bank breaking current

A

400

Rated operating voltage

V

DC110/DC220, AC220/DC220

Mechanical life

operations

20,000

5. APPLICATIONS

  • Universal 12kV Indoor Protection Platform: Six current ratings (630–3150A) and four breaking ratings (20–40kA) cover every 12kV indoor switching duty — from distribution feeders and transformer feeder protection to 3150A/40kA generator main circuits. IEC 62271-100 type certification ensures compliance readiness for utility, industrial, and EPC procurement.
  • Generator Circuit Breaker Service (3150A/40kA): The 3150A continuous rating with 40kA breaking and 100kA peak withstand provides high-current, high-fault-level protection required for generator main circuit breaker duty in industrial co-generation and distributed generation facilities.
  • Capacitor Bank and Reactive Compensation Switching: Rated for 630A single and 400A back-to-back capacitor bank switching with restrike-free vacuum interruption — suitable for power factor correction and harmonic filter circuits in utility and industrial substations.
  • High-Endurance Industrial Applications: 20,000 mechanical operations and 50 electrical operations at 31.5kA make this the preferred indoor vacuum circuit breaker for arc furnace supply, rolling mill protection, and frequent-duty substation applications where standard endurance ratings prove insufficient over the equipment lifecycle.

6. COMPETITIVE ADVANTAGES

20,000-Operation Mechanical Life — Double the Industry Standard: The ZN63(VS1)-12 achieves 20,000 mechanical close-open cycles — double the 10,000-operation rating of conventional indoor vacuum circuit breakers. Hardened alloy steel cam profiles, lifetime-lubricated sealed bearings, and precision-ground linkage pivots deliver this endurance. For frequently switched applications such as arc furnace supply, rolling mill protection, and capacitor bank control, this translates to additional decades of service life without mechanism overhaul — directly addressing the lifecycle cost versus first-cost trade-off that value engineering reviews force on procurement teams.

Class-Leading Electrical Endurance — 50 Operations at 31.5kA: The ZN63(VS1)-12 achieves 50 full-rated breaking operations at 31.5kA and 30 operations at 40kA — values that significantly exceed the 20–30 operation ratings typical of competing indoor vacuum breakers. For substations where accumulated fault operations over decades approach standard electrical endurance ratings, the 50-operation capability at 31.5kA eliminates premature interrupter replacement — removing associated outage, labor, and disposal costs from the lifecycle budget entirely.

IEC 62271-100 and KEMA Type-Test Certification: JYDQ manufactures every VS1 12KV Indoor HV Vacuum Circuit Breaker 630-3150A 20-31.5KA Embedded Pole Spring Mechanism Drawout &Fixed IEC Certified VCB under ISO 9001 with complete type-test certification at KEMA-accredited laboratories. Factory tests cover power-frequency withstand at 42kV, lightning impulse at 75kV, vacuum integrity, and mechanical timing characterization. For multi-stakeholder procurement teams spanning engineering, procurement, and project management, this documentation package provides the technical evidence base required for grid authority approval and international tender pre-qualification.

FAQ

1. What is withdrawable vacuum circuit breaker? What is its advantage?

Withdrawable vacuum circuit breaker is designed for indoor switchgear. It can be pushed in and pulled out from the cabinet easily. It is convenient for maintenance, replacement and isolation of power circuit for safety.

2. What is the rated short-circuit withstand current of vacuum circuit breaker?

The rated short-time withstand current matches the short-circuit breaking current. We can select different withstand current level according to your grid short-circuit capacity requirement.

3. Can vacuum circuit breaker be equipped with online monitoring function?

Yes, we can integrate temperature monitoring, mechanical stroke monitoring and vacuum degree monitoring modules, to realize real-time online status monitoring for the breaker.

4. Can vacuum circuit breakers operate in dusty industrial sites?

Yes. We can adopt sealed mechanism box design to prevent dust from entering the operating mechanism and vacuum interrupter, protecting internal components.

5. What warranty support do you provide for vacuum circuit breakers?

We guarantee 10 years warranty for all vacuum circuit breakers. We provide professional technical consultation for commissioning and routine inspection during warranty period.

VS1 12kV Indoor High-Voltage Vacuum Circuit Breaker

630–3150 A, 20–31.5 kA;
Features embedded poles and a spring-operated mechanism; available in withdrawable and fixed versions; IEC certified.
Self-developed mechanism structure with high-grade internal components for reliable switching in power distribution — CE certified, 10-year warranty.

Request a Quote

Featured Products

vs1 12kv indoor high voltage vacuum circuit breaker-1

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000