ZW32 Outdoor High-Voltage Vacuum Circuit Breaker

10kV/12kV/24kV/40.5kV
Intelligent Overhead-Mounted Boundary VCB with Disconnector
Self-developed mechanism structure with high-grade internal components for reliable switching in power distribution — CE certified, 10-year warranty.

Request a Quote
  • Overview

Overview

ZW32 Outdoor HV Vacuum Circuit Breaker 10KV 12KV 24KV 40.5KV — Intelligent Watching With Disconnector Pole Mounted Boundary VCB

The ZW32 Outdoor HV Vacuum Circuit Breaker 10KV 12KV 24KV 40.5KV Intelligent Watching With Disconnector Pole Mounted Boundary VCB from JYDQ is a unified three-voltage-class platform designed for overhead distribution and sub-transmission protection. This outdoor HV vacuum circuit breaker uses a vacuum interrupter with a motor-driven stored-energy spring mechanism accepting AC/DC 220V, 110V, and DC 24V control voltages. From a distribution system design perspective, the ZW32 Outdoor HV Vacuum Circuit Breaker addresses protection grade, multi-voltage compatibility, and fleet standardisation in one IEC 62271-100 and GB 1984 certified product family.

1. Product General Information

Place of Origin Zhejiang, China
Brand Name JYDQ
Model Number ZW32-12 / ZW32-24 / ZW32-40.5
Certification ISO 9001, IEC 62271-100, GB 1984
Voltage Classes 12kV / 24kV / 40.5kV
Rated Current (max) 1250A (12/24kV) / 1600A (40.5kV)
Rated Breaking Current (max) 20kA (12kV) / 31.5kA (24kV) / 31.5kA (40.5kV)
Installation Outdoor pole-mounted, three-phase common-frame
Interruption Medium Vacuum interrupter
Mechanical Life 10,000 operations

1.png2.png3.png

2. Commercial Terms

MOQ 1 Set
Price FOB Ningbo/Shanghai, on request
Packaging Export-standard wooden crate
Delivery 15–30 working days
Payment T/T, L/C at sight
Supply Ability 500 Sets per Month

The ZW32 Outdoor HV Vacuum Circuit Breaker With Disconnector Pole Mounted is available in six configurations: dual power manual switching, dual power automatic transfer, integrated primary/secondary without disconnector, integrated primary/secondary with disconnector, intelligent watching without isolating switch, and intelligent watching with isolating switch (Boundary VCB).

双电源手动.jpg双电源自动转换.jpg一二次融合不带隔离.jpg一二次融合带隔离.jpg智能看门狗不带隔离刀.jpg智能看门狗带隔离刀.jpg

3. Product Description

The ZW32 Outdoor HV Vacuum Circuit Breaker 10KV 12KV 24KV 40.5KV series delivers a unified pole-mounted platform. Unlike maintaining separate product families per voltage level, this outdoor HV vacuum circuit breaker with disconnector shares a common mechanism, spare parts inventory, and FTU interface specification — an approach that reduces lifecycle procurement and maintenance complexity for utilities operating multi-voltage overhead networks. With a rated breaking capacity of 20kA at 12kV and 31.5kA at both 24kV and 40.5kV, continuous current of up to 1600A, and an opening time of 18–45ms among the fastest in the outdoor pole-mounted class, the ZW32 Boundary VCB is engineered for dependable fault interruption at distribution and sub-transmission voltage levels.

The ZW32 Outdoor HV Vacuum Circuit Breaker Intelligent Watching With Disconnector variant integrates directly with FTU/RTU distribution automation systems. The motor-driven stored-energy spring mechanism accepts AC/DC 220V, 110V, and DC 24V control voltages — enabling direct integration with any substation auxiliary supply architecture without interposing converters. The ZW32-40.5 variant supports dual-frequency 50/60Hz operation, making the ZW32 Outdoor HV Vacuum Circuit Breaker Pole Mounted suitable for export to 60Hz markets including the Americas, Middle East, and Southeast Asia without requiring frequency-specific variant sourcing.

4. Technical Specifications

Parameter Unit ZW32-12 ZW32-24 ZW32-40.5
Rated Voltage kV 12 24 40.5
Rated Frequency Hz 50 50 50/60
Rated Current A 630/1250 630/1250 1250/1600
SC Breaking Current kA 20 20/25/31.5 25/31.5
Peak Withstand Current kA 50 50/63/80 63/80
Mechanical Life operations 10,000 10,000 10,000
SC Breaking Times times 30 30 30
LI Withstand (Phase-Gnd) kV 75 125 185
Opening Time ms 18–45 18–45 —
Main Circuit Resistance μΩ ≤100 ≤100 ≤100

5. Key Design Features

  • Unified Three-Voltage-Class Platform: The ZW32 Outdoor HV Vacuum Circuit Breaker covers 12kV, 24kV, and 40.5kV on a single mechanical platform with a shared spare parts inventory, reducing estimated fleet maintenance complexity by 30–40% compared to maintaining separate product families from multiple manufacturers.
  • Ultra-Fast Interruption — 18 to 45ms Opening Time: The ZW32 Pole Mounted Boundary VCB achieves an opening time as low as 18 milliseconds, limiting arc energy, reducing vacuum interrupter contact erosion per operation, and enabling tighter protection coordination with downstream devices including fuses and reclosers.
  • Intelligent Watching With Disconnector for Distribution Automation: The ZW32 Intelligent Watching variant with built-in isolating switch supports direct FTU/RTU integration, enabling unit protection system functions — remote switching, fault detection, and automatic isolation — without additional external switchgear on the pole.
  • IEC 62271-100 Type-Test Certification and Factory Testing: Every ZW32 Outdoor HV Vacuum Circuit Breaker unit undergoes factory testing covering dielectric withstand, main circuit resistance (100 μΩ or less), and full kinematic characterisation, backed by ISO 9001 quality management and IEC 62271-100 type-test certification to GB 1984.

6. Applications

The ZW32 Outdoor HV Vacuum Circuit Breaker Pole Mounted serves as the primary protection device for 12kV distribution, 24kV sub-transmission, and 40.5kV sub-transmission overhead feeders. In experience, engineers specifying outdoor vacuum circuit breakers often underestimate system integration challenges: choosing a pole-mounted boundary VCB in isolation is straightforward, but ensuring it integrates correctly with the upstream relay, downstream reclosers, and the distribution automation master station is where unit protection system coordination issues typically appear. The ZW32 With Disconnector addresses this with a common FTU interface specification across all three voltage classes and a multi-voltage mechanism that eliminates auxiliary power supply constraints. During commissioning and scheduled maintenance on ZW32-equipped poles, site teams must apply an appropriately rated earthing stick before any physical contact with conductors; the built-in mechanical position indicator and non-resettable operation counter assist in confirming open/closed status prior to earthing stick application.

For 40.5kV sub-transmission feeders, the ZW32 Outdoor HV Vacuum Circuit Breaker With Disconnector supports the O-0.1s-CO-3s-CO-6s-CO-60s auto-reclose sequence with a 0.1-second first dead time, enabling rapid supply restoration following transient overhead line faults. The 50/60Hz dual-frequency rating of the ZW32-40.5 confirms its suitability for both standard 50Hz networks and 60Hz export markets in the Americas and Middle East.

7. Why the ZW32 Outdoor HV Vacuum Circuit Breaker Intelligent Watching With Disconnector

You will see suppliers position outdoor vacuum circuit breakers as either voltage-class-specific for maximum technical optimisation, or platform-unified for standardisation benefits. Both framings are partially true — but for a utility operating at 12kV, 24kV, and 40.5kV, maintaining three separate breaker families means three training programmes, three spare parts inventories, and three FTU interface specifications. The ZW32 Outdoor HV Vacuum Circuit Breaker 10KV 12KV 24KV 40.5KV Intelligent Watching With Disconnector Pole Mounted Boundary VCB resolves this by delivering class-appropriate insulation ratings and breaking capacities within a single certified platform — backed by IEC 62271-100 type-test evidence and JYDQ ISO 9001 quality management.

In experience, the parameter most frequently underweighted in outdoor HV vacuum circuit breaker specification is control voltage compatibility. Engineers often discover late in a project that the substation DC bus standard does not match the breaker coil rating, requiring interposing relays that add cost and failure risk. The ZW32 Outdoor HV Vacuum Circuit Breaker With Disconnector addresses this directly with its AC/DC 220V/110V/DC 24V multi-voltage mechanism design across the complete 10KV 12KV 24KV 40.5KV voltage range.

A16c3ce0879a44ebb90aef66670a9e90aO.jpgA46fb3c2044f442c98b038a39b60e56f0x.jpgA4b27f010397b409b921add81e081aeed0.jpgA587da9f9e1e44e3681bbcc288cc6a015S.jpg

FAQ

1. What is the core working principle of your vacuum circuit breaker?

The vacuum circuit breaker uses high vacuum inside the interrupter chamber to extinguish electric arc.There is almost no gas medium inside the sealed vacuum tube, which can quickly cool and cut off the arcwhen the circuit is disconnected. This design brings low contact wear, stable breaking performance andlong mechanical life.

2. What types of vacuum circuit breakers can you provide?

We supply indoor fixed type, indoor withdrawable type, outdoor pole-mounted type and outdoor boxtype vacuum circuit breakers. Different models are suitable for cabinet installation, overhead line,distribution substation and industrial power system protection.

3. What are the main technical parameters we can customize?

We can customize rated current, short-circuit breaking current, mechanical operation cycle and auxiliary contact quantity. We can also adjust the voltage coil of operating mechanism to match local control power supply standard.

4. What certifications do your vacuum circuit breakers have?

All vacuum circuit breakers from our factory hold CE certification. We can supply CE test documents and complete technical datasheets for tender review and customs clearance.

5. What is your warranty coverage for vacuum circuit breakers?

We offer 10 years warranty for all vacuum circuit breakers. Our technical team provides remotetroubleshooting and operation guidance during the whole warranty period to guarantee stableequipment operation.

ZW32 Outdoor High-Voltage Vacuum Circuit Breaker

10kV/12kV/24kV/40.5kV
Intelligent Overhead-Mounted Boundary VCB with Disconnector
Self-developed mechanism structure with high-grade internal components for reliable switching in power distribution — CE certified, 10-year warranty.

Request a Quote

Featured Products

zw32 outdoor high voltage vacuum circuit breaker-1

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000