GKG Mining High-Voltage Switchgear

6kV/10kV
Customizable Indoor Fixed Metal-Enclosed Switchgear
Fully customizable high/low-voltage switchgear engineered to your exact specifications and site requirements — CE certified, 10-year warranty.

Request a Quote
  • Overview

Overview

Product Overview

The GKG 6kV 10kV Mining High Voltage Switchgear Customizable Indoor Fixed Metal Enclosed Power Distribution Cabinet for Mines is a purpose-engineered medium-voltage power distribution solution manufactured by JYDQ (Zhejiang, China). Designed for underground and surface mining operations, this fixed metal-enclosed indoor cabinet operates at 6kV and 10kV with eleven current ratings from 50A to 1250A, covering mining power distribution requirements from small auxiliary circuits through 1250A main feeder circuits for coal cutters, conveyors, ventilation fans, and dewatering pumps.

For most industrial applications, a general-purpose indoor switchgear is adequate. The design priorities shift in mining environments: IP43 dust and water spray protection, high fault-level short-circuit performance, integrated five-function microprocessor protection without external relays, and five-cycle auto-reclose duty certification are all required. The GKG 6kV 10kV Mining High Voltage Switchgear Customizable Indoor Fixed Metal Enclosed Power Distribution Cabinet for Mines is certified to IEC 62271-200, GB 3906, and applicable mining electrical safety standards — meeting these demands as a validated baseline.

Core Technical Specifications

Rated Voltage

10kV, 6kV

Rated Current

1250A, 1000A, 800A, 630A, 500A, 400A, 315A, 200A, 150A, 100A, 50A

Protection Class

IP43

Number of Short-circuit Breaking & Making Current Operations

Sequence: Open - 0.3s - Close - 180s - Close, 5 cycles; 14 open operations, 11 close-open operations

Rated Short-circuit Breaking Current

31.5kA (r.m.s.)

Rated Short-circuit Making Current

80kA (peak)

Rated Short-time Withstand Current

31.5kA (r.m.s.)

Rated Peak Withstand Current

80kA (peak)

Rated Short-circuit Duration

4s

Rated Number of Short-circuit Breaking Operations

30 times

Main Protection Functions

1) Short-circuit Protection 2) Overload Protection 3) Zero-sequence Overcurrent Protection 4) Zero-sequence Overvoltage Protection 5) Over & Under Voltage Protection Additional functions: Fault memory, fault query, self-inspection

Integrated Five-Function Protection

Reliability in mining power distribution depends on how design margins and protection architecture match actual operating conditions. The GKG 6kV 10kV Mining High Voltage Switchgear Customizable Indoor Fixed Metal Enclosed Power Distribution Cabinet for Mines integrates all five essential protection functions into a single factory-wired microprocessor relay, eliminating the commissioning errors and auxiliary supply failures common in distributed relay architectures.

  • Short-Circuit Protection: Instantaneous and time-delayed overcurrent tripping for phase faults at the high fault levels typical of underground mining substations.
  • Overload Protection: Inverse-time tripping coordinated with cable and transformer thermal damage curves. Overload settings must align with the upstream transformer MVA rating and thermal withstand characteristic — a coordination step experienced engineers address at specification stage rather than during commissioning.
  • Zero-Sequence Overcurrent Protection: Earth fault detection via core-balance current transformer measurement. Current transformer sizing for the zero-sequence overcurrent element must reflect the minimum earth fault current on your network. In mining systems using neutral earthing resistors, fault current may be as low as 5–10A, so relay sensitivity should be confirmed against your neutral earthing resistance at quotation stage.
  • Zero-Sequence Overvoltage Protection: Backup earth fault detection from the broken-delta voltage transformer connection, detecting high-impedance faults below the current transformer threshold — critical in underground mining substations.
  • Over and Under Voltage Protection: Equipment protection against voltage excursions from large motor starting sequences and load rejection on mining networks with conveyors, crushers, and hoisting systems.

Fault memory, fault query, and continuous self-inspection are integrated as standard, supporting post-event analysis, rapid troubleshooting, and early warning of protection system issues before they cause a failure.

a81afe91ff0d21854e9c8de94712553a.jpgd70a05c77e2bbf0c1c9b9d9bcee49908.jpgeddea63b95e4205369bccc1218501b05.jpge42887415e97d14bf0e7116c8c8aa00c.jpg

Enclosure and Construction

Many switchgear reliability problems in mining trace back not to the electrical components but to enclosure protection insufficient for the actual dust and moisture conditions, or to conductive dust on exposed busbars. This GKG cabinet addresses these failure mechanisms at the design stage.

The IP43 heavy-gauge welded steel enclosure with gasketed door seals, bottom cable entry gland plates, and anti-corrosion powder coating provides verified protection against coal and rock dust particles larger than 1mm and water spray at up to 60 degrees from vertical — higher than the IP4X dust-only rating of standard indoor switchgear. The internal busbar system is fully insulated with epoxy or heat-shrink sleeving, eliminating phase-to-phase flashover risk from conductive dust accumulation. The vacuum circuit breaker mounts on a withdrawable carriage with positive mechanical and electrical interlocks between service, test, and isolated positions, enabling safe maintenance without de-energizing the complete switchboard.

Application Scenarios

Underground Substation and Surface Processing Plant Distribution

The GKG serves as main incoming and feeder circuit breaker in underground substations at 6kV and 10kV for coal, copper, gold, and other mining operations. At surface processing plants, GKG cabinets supply power to crushing, grinding, conveying, and pumping equipment. The eleven standard current ratings, all with identical cabinet dimensions and busbar interfaces, enable complete fleet standardization — one circuit breaker spare type and one maintenance training program for the full installed base.

Ventilation and Dewatering Protection

Zero-sequence earth fault and over and under voltage functions are configured for critical ventilation fan circuits where supply continuity is a mining safety requirement. GKG cabinets protect dewatering pump motors in underground sump installations where IP43 enclosure protection withstands water spray and condensation that standard IP4X switchgear cannot sustain in service.

Differentiating Advantages

The GKG 6kV 10kV Mining High Voltage Switchgear Customizable Indoor Fixed Metal Enclosed Power Distribution Cabinet for Mines offers four mining-specific capabilities: IP43 enclosure with fully insulated busbar eliminating the leading contamination failure mode; integrated five-function protection without external relays, reducing commissioning risk and cost; five-cycle O-0.3s-CO-180s-CO duty certification for mining auto-reclose service that single-cycle switchgear cannot match; and customizable design across eleven ratings from 50A to 1250A with factory routine tests and type test records for procurement qualification.

Commercial Terms

MOQ: 1 Set. FOB Ningbo or Shanghai. Delivery: 30–50 working days. Supply: 100 Sets per month. Payment: T/T or L/C at sight. Packaging: reinforced wooden crate with moisture barrier. Custom configurations and application engineering support available from JYDQ directly.

FAQ

1. What is GKG mining high voltage switchgear used for?

GKG series high voltage switchgear is specially designed for coal mine and underground mining powerdistribution system. It is used for receiving and distributing electric energy, and protecting mining powercircuits against short-circuit and overload faults.

2. What structural characteristics does GKG mining switchgear have?

The whole equipment adopts explosion-resistant and dust-proof structure design. It meets mining safetyrequirements, with high mechanical strength and reliable sealing to adapt to underground harsh workingenvironment.

3. What core technical parameters of GKG can be customized?

We can customize rated voltage, rated current and short-circuit withstand capacity. The overall design can be adjusted according to underground power load and mine safety specification requirements.

4. What certifications do your GKG mining high voltage switchgears have?

All our GKG mining high voltage switchgears hold CE certification. We can provide CE documents and complete technical datasheets for tender submission and customs clearance.

5. What warranty support can you provide for GKG mining switchgear?

We provide 10 years warranty for all GKG mining high voltage switchgears. Our technical team provides remote operation guidance and fault analysis during the whole warranty period.

GKG Mining High-Voltage Switchgear

6kV/10kV
Customizable Indoor Fixed Metal-Enclosed Switchgear
Fully customizable high/low-voltage switchgear engineered to your exact specifications and site requirements — CE certified, 10-year warranty.

Request a Quote

Featured Products

gkg mining high voltage switchgear-1

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000